How this simulation works
- Read the scenario, then open each exhibit tab. The exhibits hold everything you need to answer the tasks.
- Complete every task, then select Submit answers. Scoring gives partial credit where a task has more than one part, the same way CompTIA can award partial credit on PBQs.
- After you submit, each task shows the correct answer and an explanation. Select Reset simulation to clear your work and try again.
- On the real CySA+ exam, PBQs are simulations. You can flag a simulation, skip it, and return to it after you finish the multiple-choice questions, and each simulation has a reset button.
CS0-004 objectives practiced:
- 2.1 Implement the appropriate vulnerability scanning method
- 2.3 Analyze data to prioritize and mitigate vulnerabilities
- 4.1 Vulnerability management reporting and communication
The organization, people, and events in this simulation are fictional. Public IP addresses come from the RFC 5737 documentation ranges and domain names use the reserved .example top-level domain, so none of them route anywhere. This is a practice activity and is not graded.
Pacing timer
Scenario
The monthly credentialed vulnerability scan at Tamberlin Health Network finished overnight. You must sort the validated findings into the organization's remediation categories so the infrastructure team can plan the week.
Apply the remediation policy exactly as written. The policy, not personal judgment, decides the category.
Exhibits
Tamberlin vulnerability remediation policy
- Emergency (fix within 48 hours): the vulnerability is listed in the CISA Known Exploited Vulnerabilities (KEV) catalog, OR the asset is internet-facing and the EPSS score is 0.50 or higher.
- Standard (fix within 30 days): any other validated finding where a fix can be applied.
- Risk exception: a fix cannot be applied to the asset. Requires compensating controls and approval by the asset owner.
- False positive: validation shows the vulnerability is not present. Close the finding and record the evidence.
- EPSS estimates the probability that a vulnerability will be exploited in the next 30 days, on a scale of 0 to 1.
Scan findings, credentialed scan, 2026-11-14
| ID | Finding | Asset | Exposure | CVSS | EPSS | In KEV | Notes |
|---|---|---|---|---|---|---|---|
| F1 | Authentication bypass in VPN appliance management portal | vpn-gw01 | Internet-facing | 9.8 | 0.94 | Yes | Vendor patch available. |
| F2 | Outdated encryption library in patient portal container image | portal-app | Internet-facing | 7.5 | 0.05 | No | Found in the application's SBOM and confirmed by the container scanner. Updated image available. |
| F3 | Remote code execution in legacy file-sharing protocol | img-ws-07 | Internal | 8.1 | 0.38 | No | MRI imaging workstation. The OS manufacturer has a fix, but the device vendor's support contract prohibits OS changes and voids the device certification if modified. |
| F4 | Web server version banner matches a vulnerable release | intranet-web02 | Internal | 7.5 | 0.21 | No | Detected from the version banner only. The host's package changelog shows the vendor backported the security fix into the installed package. |
| F5 | Missing cumulative update on database server | hr-db01 | Internal | 8.8 | 0.12 | No | Stores employee PII. Update available. |
| F6 | Remote code execution in print spooler service | 120 clinic workstations | Internal | 8.8 | 0.71 | Yes | Vendor patch available. |